Duct Carbon Dioxide (CO2) Transmitter CO2D-series

Duct Carbon Dioxide (CO2) transmitter with Humidity and Temperature Options CO2D-series

Output(s)
0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc
(One output and Two CO2 outputs available)

Available with Modbus RS485 communication, LCD Display, relay output(s), Buzzer.

Temperature and Humidity Options

Description
Duct Carbon Dioxide (CO2) transmitter CO2D-series

Duct Carbon Dioxide (CO2) transmitter CO2D-series have a
maintenance free NDIR sensor

Measuring ranges for duct Carbon Dioxide (CO2) transmitter CO2D-series are
400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm
selectable ranges with DIP switch
On request 0-1.000 ppm.

Output(s) for duct Carbon Dioxide (CO2) transmitter CO2D-series are
0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc
(One output and Two CO2 outputs available).

Estimated operating life for duct Carbon Dioxide (CO2) transmitter
CO2D-series is 15 years.

The duct Carbon Dioxide (CO2) transmitter CO2D-series have
ABC – Automatic Baseline Calculation.

Accuracy for duct Carbon Dioxide (CO2) transmitter CO2D-series is
70 ppm +3 % reading.

Power supply for duct Carbon Dioxide (CO2) transmitter CO2D-series is 24 Vac/dc.

  • "Options"

    • Modbus RS485
    • LCD Display
    • 1 x relay output , can be set individually
    • 2 x relay outputs , can be set individually
    • Buzzer
  • Temperature and Humidity Options

    • Temperature measuring ranges 0 to +50°C or -30 to +70°C
    • Temperature output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
    • Humidity measuring ranges 0 to 100% rH
    • Humidity output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
  • Ordering examples

    CO2D 51
    Duct Carbon Dioxide (CO2) room transmitter
    Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc

    CO2D 51 M
    Duct Carbon Dioxide (CO2) room transmitter
    Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
    Modbus RS485 communication

    CO2D 51 MDR2B
    Duct Carbon Dioxide (CO2) room transmitter
    Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
    Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer

    CO2D C1T1H1 MDR2B
    Carbon Dioxide (CO2) duct transmitter with Temperature and Humidity options
    CO2 output 0-10 Vdc
    TEMP. output 0-10 Vdc
    HUM. output 0-10 Vdc
    Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer

    See data sheet for wide range of different combinations.

    EDP 100
    Extra Duct Probe, length 100 mm x diameter 30 mm
    Standard duct probe length is 100 mm.
    Duct probe length can be extended to 200 mm with EDP 100
    (100 mm + 100 mm = 200 mm)